SPECIFICATIONS:

Digital Video, Camera to Base

Number of Channels

1 Per Camera

Interface

SMPTE ST259, ST292, ST424

Data Rate

270Mbps, 1.5Gbps, 3Gbps

Input/Output Level

800mVp-p

Input/Output Impedance

75 Ohms

Number of Outputs at Base

2 Per Camera


Digital Video, Base to Camera

Number of Channels

3 Per Camera

Interface

SMPTE ST259, ST292, ST424, HDMI**

Data Rate

270Mbps, 1.5Gbps, 3Gbps

Input/Output Level

800mVp-p

Input/Output Impedance

75 Ohms

Connectors

BNC, HDMI***

**HDMI camera output is only available on Return channel #3 for prompter use, only SMPTE compatible resolutions are supported. All inputs at base unit are SDI.
***Return channel #3 output has both a BNC and an HDMI connector, all other outputs are BNC only.


Video, Genlock

Number of Inputs

1 + Loop Output

Type

Analog Black Burst, Tri-Level

Impedance

75 Ohms

Connector, Camera Unit

Internal

Connector, Base Unit

BNC (x2)


Audio, Camera to Base

Type

Embedded in Camera’s SDI video

Number of Channels

Max supported by camera


Audio, Base to Camera

Number of Channels

2

Type

Balanced Analog Line-Level, mono

Level

+4dBu nominal, +24dBu max.

Connector, Camera Unit

DB9

Connector, Base Unit

DB25


Intercom

Number of Channels

2

Interface

2-Wire or 4-Wire

Compatibility

RTS, Clear-Com

Connector, Camera Unit

XLR-5

Headset MIC Type

Dynamic

Headset MIC Impedance

200 Ohms nominal

Connector, Base Unit

DB25


RCP Camera Control (Remote)

Number of Channels

1 Per Camera

Connector, Camera Unit

Internal

Connector, Base Unit

6 pin Mini-DIN (x3)


Ethernet

Number of Channels

1 Per Camera

Data Rate

10/100/1000 Base-T

Connector, Camera Unit

RJ45 Cat5e

Connector, Base Unit

RJ45 Cat5e (x3)


Timecode

Number, Base to Camera

1 per Camera

Number, Camera to Base

1, from Camera # 1 only

Inputs

Unbalanced, 15Vp-p max

Outputs

Unbalanced, 3Vp-p

Connector, Camera Unit

Internal

Connector, Base Unit

BNC


Tally/GPIO

Number, Base to Camera

3 per Camera (Red, Green, Spare)

Number, Camera to Base

1 Per Camera

Inputs

Short to GND or TTL Low to Activate

Outputs

Relay Contact Closure (30V, 2A max)

Connector, Camera Unit

DB15

Connector, Base Unit

DB25


Electro-Optical

Operating Wavelengths

1471-1611nm

Tx Laser Output Power

0dBm (Class 1 Laser)

Receiver Sensitivity

-20dBm

Fiber Compatibility

Single-mode

Optical Connector Types

opticalCON DUO, SMPTE 304M


Mechanical/Environmental

Dimensions (HxWxD)


Camera Unit

8.2” x 6.7” x 4.2”

Base Unit

3.5” x 19” x 16” (2RU)

Environmental

0 to 50°C, 0 to 95% RH, non-condensing.

Power Input, Base

IEC320, Universal Input, 90-250VAC, 50-60Hz

Power Input, Camera


Remote Power

Hybrid Fiber Connector

Local Power

Battery Mount ((Anton Bauer or (Optional) V-Mount))


Facebook Twitter LinkedIn Instagram YouTube